Oven minimum flame adjustment
Light the oven burner at max. setting.
Close the door. Turn the knob to min. After approx. 20 minutes (at least to obtain first activation of the
thermostat), proceed as follows: remove the oven knob and insert a small screwdriver outside the
thermostat, as shown in the figure 7A.
Turn the adjustment screw clockwise to increase the flame and anticlockwise to decrease it. For correct
setting, make sure the flame height is 3/4 mm.
Room ventilation
Gas appliances
This appliance is not connected to a fume exhaust device.
Therefore it must be installed and connected in compliance with
current installation regulations.
Particular attention must be paid to the applicable standards
concerning room airing.
Room ventilation
This appliance can only be installed and used in well-ventilated
rooms, according to current regulations, with openings in the
walls or with special ducts enabling proper natural or forced
ventilation, thus ensuring permanent and adequate introduction
of air necessary for correct combustion and for extraction of
vitiated air.
In particular, if there is only this gas appliance in the room, a hood
must be installed above the appliance to ensure natural and direct
extraction of the vitiated air, with a straight vertical duct of length
equal to at least twice the diameter and a minimum section of at
least 100 cm
2
.
For the indispensable introduction of fresh air in the room, a
similar opening of at least 100 cm
2
directly to the outside must be
provided at a height near floor level so as not to be obstructed on
the inside or outside of the wall and not to hinder the correct
combustion of the burners and the regular extraction of vitiated
air, and with a height difference of at least 180 cm with respect to
the outlet opening.
The quantity of air necessary for combustion must not be less
than 2 m
3
/h for every kW of power (see total power in kW on the
appliance rating plate).
In all other cases, when there are other appliances in the same
room, or when direct natural ventilation is not possible and
indirect natural ventilation of forced ventilation has to be created,
contact a qualified specialist for carrying out installation and
preparing the possible ventilation system in strict compliance with
current regulations.
Flues already used by other appliances must not be used for
exhausting combustion products.