PRECAUTIONS FOR USE
Warning:
Make sure to insert the power plug securely.
Insecure insertion of the plug may cause
electrocution or fire.
Never unplug the machine while running.
Do not damage the cord or use an unapproved
cord.
Do not plug other electric appliances into the
same socket or use extension cords.
Never operate the air conditioner with wet
hands.
Do not pull the plug out by the cord. This could
cause the cord to overheat and catch fire.
Turn off the air conditioner and pull out the plug
when cleaning the air conditioner. This will
prevent electrocution or injury.
The rated voltage of this air conditioner is 220-
240V with a tolerance of ±22V for fluctuation.
The compressor will vibrate if the voltage is too
low, causing damage to the cooling system.
If you notice anything unusual (e.g. burnt smell),
switch off the power supply immediately and
contact the Whirlpool Authorized Service
Center nearest you.
If the abnormal condition continues, the air
conditioner could be damaged and could also
cause electrocution or fire.
Grounding: The unit must be reliably grounded.
The grounding cable must be connected to the
special grounding system in the building.
If the building does not have a grounding
system, ask an expert electrician to install one.
Never connect the grounding cable to a gas
pipe, water pipe, sewage pipe or other unless
the professional considers it reliable.
Make sure to unplug air conditioner when not in
use for an extended period. Accumulation of
dust could cause heating or fire.
Set the room temperature appropriately. The
difference between indoor and outdoor
temperature should be 5°C.
Appropriate adjustment of the temperature
setting serves to reduce consumption.
When the air conditioner is running, do not
leave doors and windows open in the room.
This will prevent loss of effectiveness of the air
conditioner.
Never block the air inlet or outlet of indoor and
outdoor unit, as this will decrease the effect of
the air conditioner or cause it to shut down or
even catch fire.
Spray cans, chemicals and gas tanks must be
placed at least 1m away from the indoor and
outdoor unit; they could cause fire or explosion
Make sure to mount the outdoor unit on a
sturdy base. If the base is damaged and
unsteady, the unit could fall and cause injury.
Do not stand or place anything on the outdoor
unit. Persons or objects falling from the unit
could cause injuries.
Do not repair the air conditioner yourself.
Incorrect repairs could cause electrocution or
fire. Contact the Whirlpool Authorized Service
Center nearest you for repairs.
Adjust the air flow and direction properly. When
the air conditioner is running, you can adjust the
air flow direction by setting the upper/lower
guide louver position using the remote control
or handle.
Never reach with your finger or a stick into the
indoor or outdoor unit.
Never blow the air directly at pets or plants, as
this may harm them.
Never spray water onto the unit or wash the air
conditioner with water.
Never let the air conditioner blow on a heat
source. This could put the flame out and cause
carbon monoxide poisoning.
To avoid any harm to your health, do not blow
the cold air on your body too long or lower the
room temperature too much.
This air conditioner cannot be used for drying
clothes or chilling foods.
Warning:
Do not cut or damage the power cords and
control lines. Any damaged power cords and
signal control lines of the air conditioner must
be replaced by qualified technicians with special
cords.
Persistent abnormality indicates that the air
conditioner may be damaged with the
consequent risk of electric shock or fire. This
may cause an electric shock.
To prevent fire always use a special power
supply circuit.
Disconnect the air conditioner from the power
supply if it is to be left unused for a long period.
For 18-23K, 230V, with a tolerable fluctuation of
±23V. The compressor is subject to strong
vibrations under very low voltages which can
damage the refrigerating system. Electrical
elements are easily damaged by high voltage.
Vista de página 0
1 2 3 4 5 6 ... 21 22

Resumo do Conteúdo

Página 1 - PRECAUTIONS FOR USE

26PRECAUTIONS FOR USEWarning:• Make sure to insert the power plug securely.Insecure insertion of the plug may causeelectrocution or fire.• Never unplu

Página 2 - INSTRUCTIONS FOR USE

Warning:Do not attempt to repair the air conditioner yourself. Incorrect repairs may cause electrocution orfire, so please contact the Whirlpool Autho

Página 3

36Malfunction CauseIndoor unit makes noise. • The sound comes from the fan or compressor relay switching over(close/open).• Air conditioner may make n

Página 4 - HOW TO USE THE REMOTE CONTROL

37INSTALLATION SERVICE - PRECAUTIONSON INSTALLATIONImportant Precaution1. The air-conditioning unit must be installedaccording to national wiring rule

Página 5 - Remote Control

38ELECTRICAL SAFETY REQUIREMENTS1. The power supply must be of rated voltage withspecial circuitry for air-conditioning. Thediameter of the power cord

Página 6

39INSTALLATION DIMENSION DRAWINGSAMC 996 - 9k BtuAMC 998 - 12k BtuFrom the ceilingOver 15cmOver 15cmOver 15cmFrom the WallFrom the WallAbove the floor

Página 7

40AMD 009 - 18k BtuFrom the ceilingOver 15cmOver 15cmOver 15cmFrom the WallFrom the WallAbove the floorOver 300cmOver 240cmAir suction sideFrom obstac

Página 8 - CLEANING AND MAINTENANCE

41INSTALLING INDOOR UNITInstalling Wall-Mount Frame1. Level with plumb line or spirit level. As the drain outlet is on the left side, it is better for

Página 9

42Connection of Indoor and Outdoor Cables1. Pull open the front panel;2. Unscrew the screw fastening the covering plate onterminal board. (See Fig. 1)

Página 10 - TROUBLESHOOTING

43Installing Connecting Pipe1. The tapered end of the connecting pipe must be in line with the corresponding tape face of the valvejoint.2. Tighten th

Página 11

44INSTALLING OUTDOOR UNITCable connection1. Remove the handle on the right side plate of the outdoor unit (one screw).2. Remove the cable clamp, conne

Página 12 - ON INSTALLATION

27• Ensure that the power supply is suitablyprotected by a special circuit with air breaker.The air conditioner automatically starts or stopsaccording

Página 13

45Vacuum-pumping and Leakage Inspection1. Remove the nut cover at the shutoff valve.2. Align with the center of the fitting pipe andmanually tighten t

Página 14 - AMC 998 - 12k Btu

46CHECKS AND TEST RUN AFTERINSTALLATIONCheck Items After InstallationTe s t R u n1. Preparation of Test Run• Do not switch on the power before all in

Página 15 - AMD 009 - 18k Btu

47ELECTRIC HEATING BELTELECTRIC HEATING BELT FOR INVERTER MODEL AMC 996 - 998 ONLYIn case of malfunction of the outdoor temperature sensor, both elect

Página 16 - INSTALLING INDOOR UNIT

28DESCRIPTION OF AIR CONDITIONER1. Power plug (AMC 996/998)2. Terminal board cover plate3. Key switch4. Front panel5. Filter6. Guide louver7. Display8

Página 17 - Yellow-Green

29HOW TO USE THE REMOTE CONTROLOperating Guideline - General Procedures1. After the main unit is connected to power, press the ON/OFFkey on the remote

Página 18

30UP/DOWNUP/DOWN KeyPress these two keys when in COOL, DRY, FAN or HEAT mode to set a temperature between 16 and30°C. The temperature of each mode can

Página 19 - INSTALLING OUTDOOR UNIT

31CLOCKCLOCK keyWhen you press of this key, the CLOCK icon will start to blink and enter the clock adjustment mode. Inclock adjustment mode pressing t

Página 20

32STORAGE AND TIPS FOR USING THE RCHow to insert the batteries1. Unscrew the screw on the battery cover.2. Gently press down on the battery cover and

Página 21 - INSTALLATION

33CLEANING AND MAINTENANCEWarning• Make sure to stop the unit and unplug it beforecleaning your air conditioner. Otherwise youmay risk electrocution.•

Página 22 - ELECTRIC HEATING BELT

341. Removing the air filterGrasp the groove on the two ends of the frontpanel. Pull as shown by the arrow with force toopen the front panel at an ang