HOW TO USE THE HOB
WARNING
Do not let the burner ame extend beyond the edge of the pan.
IMPORTANT: when the hob is in use, the entire hob area may become hot.
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum ame setting.
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts o the gas supply to the burner if the ame goes out accidentally (because of sudden draught, an interruption in the gas
delivery, boiling over of liquids, etc.).
The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit, wait at least one minute before
trying to light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner dicult, it is advisable to repeat the operation with
the knob turned to small ame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this case, repeat the operations
described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE: in case of installation of a hood above the cooktop, please refer to
the hood instructions for the correct distance.
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
LIQUEFIED
PETROLEUM GAS
(Propane) G31
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6W
314 l/h
157 l/h
95 l/h
4 ring
Semi-rapid
Auxiliary
138 T2A
95
78 A
3,30
1,65
1,00
1,90
0,35
0,30
4 ring
Semi-rapid
Auxiliary
92 T4
67
50
3,30
1,65
1,00
236 g/h
118 g/h
71 g/h
1,90
0,35
0,30
2,20
0,35
0,30
4 ring
Semi-rapid
Auxiliary
92 T4
67
50
3,30
1,65
1,00
240 g/h
120 g/h
73 g/h
17
20
20
25
20
25
28-30
37
25
30
35
45
Total rated
consumption
Rated thermal
owrate (kW)
Model
conguration
Air required (m) for
burning 1 m of gas
Type of gas used
Type of gas
used
Type of burner Injector
marking
kW
min. rat. mx.
G20 20 mbar
G25 25 mbar
G30 28-30 mbar
G31 37 mbar
3 burners
3 burners
3 burners
3 burners
5,95
5,95
5,95
5,95
567 l/h
659 l/h
433 g/h
425 g/h
9,52
8,187
30,94
23,80
INJECTORS TABLE CATEGORY II2E+3+
LIQUEFIED
PETROLEUM GAS
(Butane) G30
NATURAL GAS
(Methane) G20
NATURAL GAS
(Methane) G25
4 ring
Semi-rapid
Auxiliary
138 T2A
95
78 A
3,30
1,65
1,00
365 l/h
183 l/h
111 l/h
2,20
0,35
0,30
2,20
0,45
0,35
BE FR