20
30
60
40
Top 30 mm Top 60 mm
ADJUSTMENT TO DIFFERENT TYPES OF GAS
This operation must be performed by a qualied technician.
If the appliance is intended to operate with a dierent gas from the gas type stated on the rating plate and information label on the top of the hob, change the
injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction:
• the gas injector must be changed by After Sales Service or a qualied technician;
• injector not supplied with the appliance must be ordered from After Sales Service;
• adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience diculty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner
tap if found to be faulty.
REPLACING THE INJECTORS (see the injector table in the Instruction)
• Remove grids (A).
• Extract burners (B).
• Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector
to be replaced.
• Replace it with the injector suitable for the new type of gas.
• Re-assemble the injector in (D).
• If you have a multiple crown burner use side spanner to replace the injector (E).
Before installing the hob, remember to ax the gas calibration plate supplied with the injectors in
such a way that it covers the existing information relating to gas calibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows:
• tighten screw to reduce the ame height (-);
• loosen screw to increase the ame height (+).
The adjustment must be performed with the tap in minimum gas setting position (small ame) :
• the primary air of the burners does not need to be adjusted;
• at this stage, light up the burners and turn the knobs from max position to minimum position
to check ame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.
REFERENCE TO LOCAL REGULATIONS
The appliance is supplied with a 1/2” threaded conical end to be connected to the gas supply (according to ISO regulations ISO 7/1 RP 1/2).
The connection must be eected in accordance with standard NBN D 51-003 using rigid piping or in accordance with specications sheet A.R.G.B./03 using
exible tubing.
The appliance must be installed complete with an AGB-approved stop valve.
The installation and maintenance of the appliance must be carried out by a qualied skilled technician in accordance with the regulations in force, and in particular:
• Decree of 2 August 1977
Technical and Safety Rules applicable to fuel gas and liqueed hydrocarbon installations located within residential buildings and outbuildings.
• Standard DTU P 45 -204
Gas installations (formerly DTU no. 61-1 -Gas installations April 1982 + supplement no. I of July 1984).