INSTALLATION INSTRUCTIONSSLIDE-IN ELECTRIC RANGESINSTRUCTIONS D’INSTALLATION DES CUISINIÈRES ÉLECTRIQUES ENCASTRABLETable of Contents/Table des matièr
105. Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.6. Connect line 1 (
111. Part of metal ground strap must be cut out and removed.2. Use Phillips screwdriver to remove the ground-link screw from the back of the range. Sa
123-wire connection: Direct WireUse this method only if local codes permit connecting ground conductor to neutral supply wire.1. Pull the conduit thro
13Complete Installation1. Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.2
14SÉCURITÉ DE LA CUISINIÈRERisque possible de décès ou de blessure grave si vous ne suivez pas immédiatement les instructions. Risque possible de décè
15EXIGENCES D'INSTALLATIONOutillage et piècesRassembler les outils et pièces nécessaires avant de commencer l'installation. Lire et suivre l
16Dimensions du produit*La cuisinière peut être surélevée d'environ 1" (2,5 cm) en ajustant les pieds de nivellement.**Dans le cas d'un
17Spécifications électriquesSi le code en vigueur le permet et qu’un conducteur distinct de liaison à la terre est utilisé, on recommande qu’un électr
18INSTRUCTIONS D'INSTALLATIONDéballage de la cuisinière1. Ôter les matériaux d'emballage, le ruban adhésif et le film protecteur de la cuisi
193. Déterminer et marquer l'axe central de l'espace à découper. On peut installer la bride de montage du côté gauche ou droit du découpage
2RANGE SAFETYYou can be killed or seriously injured if you don't immediately You can be killed or seriously injured if you don'tfollow All
9. Mettre l'appareil sous tension. Mettre en marche les brûleurs de surface et le four. Pour des instructions spécifiques concernant l'utili
3INSTALLATION REQUIREMENTSTools and PartsGather the required tools and parts before starting installation. Read and follow the instructions provided w
4Cabinet DimensionsCabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4
5The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type
6INSTALLATION INSTRUCTIONSUnpack Range1. Remove shipping materials, tape and protective film from the range. Keep cardboard bottom under range.2. Remo
74. Drill two ¹⁄₈" (3 mm) holes that correspond to the bracket holes of the determined mounting method. See below.Floor Mounting Wall Mounting5.
84. Add strain relief.Style 1: Power supply cord strain relief Assemble a UL listed strain relief in the opening. Feed the power supply cord through
9 Assemble a UL listed conduit connector in the opening. Feed the flexible conduit through the strain relief, allowing enough slack to easily attach