CLEANING THE HOB PARTS (Appendix A) – See drawing below for parts removal guides.
To reinstall the parts (grids, caps, rings and burners) reverse depicted operation.
Gas Type NATURAL @ 1.00 kPa
(test point pressure)
UNIVERSAL LP @ 2.75 kPa
(inlet pressure)
Burner Nominal Gas
Consumption (MJ/h)
Nominal Injector
Size (mm)
Nominal Gas
Consumption (MJ/h)
Nominal Injector
Size (mm)
Front RHS Auxiliary 3.7 0.87 3.8 0.56
Rear RHS Semi-Rapid 6.6 1.17 7.0 0.75
Front LHS Semi-Rapid 6.6 1.17 7.0 0.75
Rear LHS Rapid10.71.5011.70.96
Middle CHS Ultra Rapid15.21.8016.01.12
Total 42.8 45.5
The technical information are situated in the rating plate on
the bottom side of the appliance.
Note: A duplicate Data Plate provided with the appliances
should be affixed adjacent to the appliance nearby on a
cabinet or area where it is easily accessible for reference.
Before installing the hotplate consider the location of the
gas supply and routing the gas line.
52
112
307
ELECTRICAL
CONNECTION POINT
GAS CONNECTION
POINT