NOTE: if the distance “A” between the wall cabinets is between
600 mm and 680 mm, the height “B” must be a minimum of 520 mm.
if the distance “A” between the wall cabinets is greater than the width
of the hob, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the hob, please refer to the hood
instructions fot the correct distance.
P/B3H2II YROGETACELBAT SROTCEJNI
Type of gas used Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Rapid129 B3.00286 l/h0.60
17 20 25Semi-rapid 97 1.65 157 l/h0.35
Auxiliary 74 B1.0095 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Rapid863.00218 g/h0.60
25 30 35
Semi-rapid 65 1.65 120 g/h 0.35
Auxiliary501.0073 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 1 R - 2 SR - 1 AUX 7.30 715 l/h9.52
G30/G31 30 mbar 1 R - 2 SR - 1 AUX 7.30 545 g/h30.94
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz