+3H2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Triple crown 132 A3.30314 l/h2.20
17 20 25
Rapid129 B3.00286 l/h0.60
Semi-rapid971.65157 l/h0.35
Auxiliary74 B1.0095 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Triple crown 92 3.30 240 g/h1.90
20 28-3035
Rapid863.00218 g/h0.60
Semi-rapid 65 1.65 120 g/h0.35
Auxiliary501.0073 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Triple crown 92 3.30 236 g/h1.90
25 37 45
Rapid863.00214 g/h0.60
Semi-rapid 65 1.65 118 g/h0.35
Auxiliary501.0071 g/h0.30
Type of gas used Model conguration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar 3C - 1 R - 2 SR - 1 AUX 10.601009 l/h9.52
G30 28-30 mbar 3C - 1 R - 2 SR - 1 AUX 10.60771 g/h30.94
G31 37 mbar 3C - 1 R - 2 SR - 1 AUX 10.60757 g/h23.80
ELECTRIC SUPPLY: 230 V ~ 50 Hz