WOK ADAPTER
INJECTORS TABLE CATEGORY II2H3+
Type of gas
used
Type of burner Injector
marking
Rated thermal
flow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
kW kW min. rat. max.
NATURAL GAS
(Methane) G20
Triple crown 132 A 3.30 314 l/h 2.20
17 20 25
Rapid 129 B 3.00 286 l/h 0.60
Semi-rapid 97 1.65 157 l/h 0.35
Auxiliary 74 B 1.00 95 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Triple crown 92 3.30 240 g/h 1.90
20 28-30 35
Rapid 86 3.00 218 g/h 0.60
Semi-rapid 65 1.65 120 g/h 0.35
Auxiliary 50 1.00 73 g/h 0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Triple crown 92 3.30 236 g/h 1.90
25 37 45
Rapid 86 3.00 214 g/h 0.60
Semi-rapid 65 1.65 118 g/h 0.35
Auxiliary 50 1.00 71 g/h 0.30
Type of gas used Model configuration
5 BURNERS
Rated thermal flow
rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1 m
3
of gas
G20 20 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 1009 l/h 9.52
G30 28-30 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 771 g/h 30.94
G31 37 mbar 3C - 1 R - 2 SR - 1 AUX 10.60 757 g/h 23.80
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz